Specification
Input | |
Range / Frequency(50Hz±5%) | 145~300V AC |
Output | |
Voltage / Transfer Time | 230V ± 9% AC / <6ms |
Regulator on Mains / Regulator on Battery | Automatic Voltage Regulation / Pulse Width Modulation |
Protection | |
Unit Input / Noise | Fuse Protection / Noise Filter |
Short Circuit (Line) / Short Circuit (Inverter) | Fuse Protection / Pulse to Pulse Electronic active Protection |
Battery | |
Type / Recharge Time | SMF / 2~5 Hrs. (depending on the status of Battery) |
Backup Time/ Batery Rating | 10 ~20mins. (Load 1PC) / 12V 7.2AH |
Battery Backup (Sound beeping) | 1 Beep Per 10 sec. (Approx.) |
Alarm | |
Low Battery | 2 Beep Per 2 sec. (Approx.) |
No Load | 1 Beep Per 2 sec. (Approx.) |
Short Circuit / Overload | Sound Beeping Continuously / Rapid |
LED Display | |
Green | Mains mode operation / AVR Working |
Red / Orange | Inverter output from battery |
Physical | |
Size (L x W x H) | (310x90x170)mm |
Weight (Approx.) | 7Kg. |
Environment | |
Operating Temperature / Rel. Humidity | 0ºC ~ 48ºC ; 32ºF ~ 120ºF / 0 to 90% non-condensing |
Noise | |
Audible Noise level | <35dB, distance 1 meter from UPS |
Warranty | 2 Years |
Note | ***Features, Price and Specifications are subject to change without notice. |
Features
Salient Features
Optimized SINEWAVE Performance: This Microtek E² Series UPS uses Energy Efficiently, and the output waveform is optimized to perform like Sinewave.
Inverter/Generator Compatible: This Microtek E² Series UPS has been designed to work with Inverters and Generators. This UPS will consider the input from Inverter or Generator as mains and keep providing Extended Backup to the computer, without discharging its own battery.
No Load Shutdown: In case No load is connected to the UPS, it will sense the load condition and automatically Shut Down after 3 minutes to protect unnecessary discharge of battery.
Fast Battery Charging: This UPS utilizes unique 5 Step High Frequency SMPS Technology to charge the battery in less than 5 hours, in order to keep your UPS ready immediately for next emergency.
Extended AVR Range of 145~300 volts: When the voltage fluctuates to as low as 150 volts & as high as 290 volts, this UPS gives you the corrected line voltage output of 230 volts ± 9% and doesn't switch the UPS to "Battery Backup mode".
Over Load / Short Circuit Protection: If the UPS is excessively overloaded in backup mode or encounters a short circuit, it will go into protection mode. The output will be shut down in this case and warn you to correct the load condition.
Battery Deep Discharge / Over Charge Protection: The UPS has in-built electronic protection circuit which protects the batteries from getting deep discharged or over charged.